모두의 코드
CMPXCHG (Intel x86/64 assembly instruction)

작성일 : 2020-09-01 이 글은 2624 번 읽혔습니다.

CMPXCHG

Compare and Exchange

참고 사항

아래 표를 해석하는 방법은 x86-64 명령어 레퍼런스 읽는 법 글을 참조하시기 바랍니다.

Opcode/
Instruction

Op/
En

64-Bit
Mode

Compat/
Leg Mode

Description

0F B0/r
CMPXCHG r/m8 r8

MR

Valid

Valid*

Compare AL with r/m8. If equal, ZF is set and r8 is loaded into r/m8. Else, clear ZF and load r/m8 into AL.

REX + 0F B0/r
CMPXCHG r/m8** r8

MR

Valid

N.E.

Compare AL with r/m8. If equal, ZF is set and r8 is loaded into r/m8. Else, clear ZF and load r/m8 into AL.

0F B1/r
CMPXCHG r/m16 r16

MR

Valid

Valid*

Compare AX with r/m16. If equal, ZF is set and r16 is loaded into r/m16. Else, clear ZF and load r/m16 into AX.

0F B1/r
CMPXCHG r/m32 r32

MR

Valid

Valid*

Compare EAX with r/m32. If equal, ZF is set and r32 is loaded into r/m32. Else, clear ZF and load r/m32 into EAX.

REX.W + 0F B1/r
CMPXCHG r/m64 r64

MR

Valid

N.E.

Compare RAX with r/m64. If equal, ZF is set and r64 is loaded into r/m64. Else, clear ZF and load r/m64 into RAX.

* See the IA-32 Architecture Compatibility section below.

**In 64-bit mode, r/m8 can not be encoded to access the following byte registers if a REX prefix is used: AH, BH, CH, DH.

Instruction Operand Encoding

Op/En

Operand 1

Operand 2

Operand 3

Operand 4

MR

ModRM:r/m (r, w)

ModRM:reg (r)

NA

NA

Description

Compares the value in the AL, AX, EAX, or RAX register with the first operand (destination operand). If the two values are equal, the second operand (source operand) is loaded into the destination operand. Otherwise, the destination operand is loaded into the AL, AX, EAX or RAX register. RAX register is available only in 64-bit mode.

This instruction can be used with a LOCK prefix to allow the instruction to be executed atomically. To simplify the interface to the processor's bus, the destination operand receives a write cycle without regard to the result of the comparison. The destination operand is written back if the comparison fails; otherwise, the source operand is written into the destination. (The processor never produces a locked read without also producing a locked write.)

In 64-bit mode, the instruction's default operation size is 32 bits. Use of the REX.R prefix permits access to addi-tional registers (R8-R15). Use of the REX.W prefix promotes operation to 64 bits. See the summary chart at the beginning of this section for encoding data and limits.

IA-32 Architecture Compatibility

This instruction is not supported on Intel processors earlier than the Intel486 processors.

Operation

(* Accumulator = AL, AX, EAX, or RAX depending on whether a byte, word, doubleword, or quadword comparison is being performed *)
TEMP <- DEST
IF accumulator = TEMP
    THEN
          ZF <- 1;
          DEST <- SRC;
    ELSE
          ZF <- 0;
          accumulator <- TEMP;
          DEST <- TEMP;
FI;

Flags Affected

The ZF flag is set if the values in the destination operand and register AL, AX, or EAX are equal; otherwise it is cleared. The CF, PF, AF, SF, and OF flags are set according to the results of the comparison operation.

Protected Mode Exceptions

#GP(0)

  • If the destination is located in a non-writable segment.

  • If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.

  • If the DS, ES, FS, or GS register contains a NULL segment selector.

#SS(0)

  • If a memory operand effective address is outside the SS segment limit.

#PF(fault-code)

  • If a page fault occurs.

#AC(0)

  • If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.

#UD

  • If the LOCK prefix is used but the destination is not a memory operand.

Real-Address Mode Exceptions

#GP

  • If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.

#SS

  • If a memory operand effective address is outside the SS segment limit.

#UD

  • If the LOCK prefix is used but the destination is not a memory operand.

Virtual-8086 Mode Exceptions

#GP(0)

  • If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.

#SS(0)

  • If a memory operand effective address is outside the SS segment limit.

#PF(fault-code)

  • If a page fault occurs.

#AC(0)

  • If alignment checking is enabled and an unaligned memory reference is made.

#UD

  • If the LOCK prefix is used but the destination is not a memory operand.

Compatibility Mode Exceptions

Same exceptions as in protected mode.

64-Bit Mode Exceptions

#SS(0)

  • If a memory address referencing the SS segment is in a non-canonical form.

#GP(0)

  • If the memory address is in a non-canonical form.

#PF(fault-code)

  • If a page fault occurs.

#AC(0)

  • If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.

#UD

  • If the LOCK prefix is used but the destination is not a memory operand.