모두의 코드
FLDCW (Intel x86/64 assembly instruction)
FLDCW
Load x87 FPU Control Word
참고 사항
아래 표를 해석하는 방법은 x86-64 명령어 레퍼런스 읽는 법 글을 참조하시기 바랍니다.
Opcode | Instruction | 64-Bit | Compat/ | Description |
---|---|---|---|---|
D9 /5 | FLDCW m2byte | Valid | Valid | Load FPU control word from m2byte. |
Description
Loads the 16-bit source operand into the FPU control word. The source operand is a memory location. This instruc-tion is typically used to establish or change the FPU's mode of operation.
If one or more exception flags are set in the FPU status word prior to loading a new FPU control word and the new control word unmasks one or more of those exceptions, a floating-point exception will be generated upon execution of the next floating-point instruction (except for the no-wait floating-point instructions, see the section titled "Soft-ware Exception Handling" in Chapter 8 of the Intel(R) 64 and IA-32 Architectures Software Developer's Manual, Volume 1). To avoid raising exceptions when changing FPU operating modes, clear any pending exceptions (using the FCLEX or FNCLEX instruction) before loading the new control word.
This instruction's operation is the same in non-64-bit modes and 64-bit mode.
Operation
FPUControlWord <- SRC;
FPU Flags Affected
C0, C1, C2, C3 undefined.
Floating-Point Exceptions
None; however, this operation might unmask a pending exception in the FPU status word. That exception is then generated upon execution of the next "waiting" floating-point instruction.
Protected Mode Exceptions
#GP(0)
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.
If the DS, ES, FS, or GS register is used to access memory and it contains a NULL segment selector.
#SS(0)
If a memory operand effective address is outside the SS segment limit.
#NM
CR0.EM[bit 2] or CR0.TS[bit 3] = 1.
#PF(fault-code)
If a page fault occurs.
#AC(0)
If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.
#UD
If the LOCK prefix is used.
Real-Address Mode Exceptions
#GP
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.
#SS
If a memory operand effective address is outside the SS segment limit.
#NM
CR0.EM[bit 2] or CR0.TS[bit 3] = 1.
#UD
If the LOCK prefix is used.
Virtual-8086 Mode Exceptions
#GP(0)
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.
#SS(0)
If a memory operand effective address is outside the SS segment limit.
#NM
CR0.EM[bit 2] or CR0.TS[bit 3] = 1.
#PF(fault-code)
If a page fault occurs.
#AC(0)
If alignment checking is enabled and an unaligned memory reference is made.
#UD
If the LOCK prefix is used.
Compatibility Mode Exceptions
Same exceptions as in protected mode.
64-Bit Mode Exceptions
#SS(0)
If a memory address referencing the SS segment is in a non-canonical form.
#GP(0)
If the memory address is in a non-canonical form.
#NM
CR0.EM[bit 2] or CR0.TS[bit 3] = 1.
#MF
If there is a pending x87 FPU exception.
#PF(fault-code)
If a page fault occurs.
#AC(0)
If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.
#UD
If the LOCK prefix is used.
댓글을 불러오는 중입니다..