모두의 코드
REP, REPE, REPZ, REPNE, REPNZs (Intel x86/64 assembly instruction)

작성일 : 2020-09-01 이 글은 2211 번 읽혔습니다.

REP, REPE, REPZ, REPNE, REPNZ

Repeat String Operation Prefix

참고 사항

아래 표를 해석하는 방법은 x86-64 명령어 레퍼런스 읽는 법 글을 참조하시기 바랍니다.

Opcode

Instruction

Op/
En

64-Bit
Mode

Compat/
Leg Mode

Description

F3 6C

REP INS m8 DX

NP

Valid

Valid

Input (E)CX bytes from port DX into ES:[(E)DI].

F3 6C

REP INS m8 DX

NP

Valid

N.E.

Input RCX bytes from port DX into [RDI].

F3 6D

REP INS m16 DX

NP

Valid

Valid

Input (E)CX words from port DX into ES:[(E)DI.]

F3 6D

REP INS m32 DX

NP

Valid

Valid

Input (E)CX doublewords from port DX into ES:[(E)DI].

F3 6D

REP INS r/m32 DX

NP

Valid

N.E.

Input RCX default size from port DX into [RDI].

F3 A4

REP MOVS m8 m8

NP

Valid

Valid

Move (E)CX bytes from DS:[(E)SI] to ES:[(E)DI].

F3 REX.W A4

REP MOVS m8 m8

NP

Valid

N.E.

Move RCX bytes from [RSI] to [RDI].

F3 A5

REP MOVS m16 m16

NP

Valid

Valid

Move (E)CX words from DS:[(E)SI] to ES:[(E)DI].

F3 A5

REP MOVS m32 m32

NP

Valid

Valid

Move (E)CX doublewords from DS:[(E)SI] to ES:[(E)DI].

F3 REX.W A5

REP MOVS m64 m64

NP

Valid

N.E.

Move RCX quadwords from [RSI] to [RDI].

F3 6E

REP OUTS DX r/m8

NP

Valid

Valid

Output (E)CX bytes from DS:[(E)SI] to port DX.

F3 REX.W 6E

REP OUTS DX r/m8*

NP

Valid

N.E.

Output RCX bytes from [RSI] to port DX.

F3 6F

REP OUTS DX r/m16

NP

Valid

Valid

Output (E)CX words from DS:[(E)SI] to port DX.

F3 6F

REP OUTS DX r/m32

NP

Valid

Valid

Output (E)CX doublewords from DS:[(E)SI] to port DX.

F3 REX.W 6F

REP OUTS DX r/m32

NP

Valid

N.E.

Output RCX default size from [RSI] to port DX.

F3 AC

REP LODS AL

NP

Valid

Valid

Load (E)CX bytes from DS:[(E)SI] to AL.

F3 REX.W AC

REP LODS AL

NP

Valid

N.E.

Load RCX bytes from [RSI] to AL.

F3 AD

REP LODS AX

NP

Valid

Valid

Load (E)CX words from DS:[(E)SI] to AX.

F3 AD

REP LODS EAX

NP

Valid

Valid

Load (E)CX doublewords from DS:[(E)SI] to EAX.

F3 REX.W AD

REP LODS RAX

NP

Valid

N.E.

Load RCX quadwords from [RSI] to RAX.

F3 AA

REP STOS m8

NP

Valid

Valid

Fill (E)CX bytes at ES:[(E)DI] with AL.

F3 REX.W AA

REP STOS m8

NP

Valid

N.E.

Fill RCX bytes at [RDI] with AL.

F3 AB

REP STOS m16

NP

Valid

Valid

Fill (E)CX words at ES:[(E)DI] with AX.

F3 AB

REP STOS m32

NP

Valid

Valid

Fill (E)CX doublewords at ES:[(E)DI] with EAX.

F3 REX.W AB

REP STOS m64

NP

Valid

N.E.

Fill RCX quadwords at [RDI] with RAX.

F3 A6

REPE CMPS m8 m8

NP

Valid

Valid

Find nonmatching bytes in ES:[(E)DI] and DS:[(E)SI].

F3 REX.W A6

REPE CMPS m8 m8

NP

Valid

N.E.

Find non-matching bytes in [RDI] and [RSI].

F3 A7

REPE CMPS m16 m16

NP

Valid

Valid

Find nonmatching words in ES:[(E)DI] and DS:[(E)SI].

F3 A7

REPE CMPS m32 m32

NP

Valid

Valid

Find nonmatching doublewords in ES:[(E)DI] and DS:[(E)SI].

F3 REX.W A7

REPE CMPS m64 m64

NP

Valid

N.E.

Find non-matching quadwords in [RDI] and [RSI].

F3 AE

REPE SCAS m8

NP

Valid

Valid

Find non-AL byte starting at ES:[(E)DI].

F3 REX.W AE

REPE SCAS m8

NP

Valid

N.E.

Find non-AL byte starting at [RDI].

F3 AF

REPE SCAS m16

NP

Valid

Valid

Find non-AX word starting at ES:[(E)DI].

F3 AF

REPE SCAS m32

NP

Valid

Valid

Find non-EAX doubleword starting at ES:[(E)DI].

Instruction

Op/
En

64-Bit
Mode

Compat/
Leg Mode

REPE SCAS m64

NP

Valid

N.E.

REPNE CMPS m8, m8

NP

Valid

Valid

REPNE CMPS m8, m8

NP

Valid

N.E.

REPNE CMPS m16, m16

NP

Valid

Valid

REPNE CMPS m32, m32

NP

Valid

Valid

REPNE CMPS m64, m64

NP

Valid

N.E.

REPNE SCAS m8

NP

Valid

Valid

REPNE SCAS m8

NP

Valid

N.E.

REPNE SCAS m16

NP

Valid

Valid

REPNE SCAS m32

NP

Valid

Valid

REPNE SCAS m64

NP

Valid

N.E.

Opcode Description

F3 REX.W AF Find non-RAX quadword starting at [RDI].

F2 A6 Find matching bytes in ES:[(E)DI] and DS:[(E)SI].

F2 REX.W A6 Find matching bytes in [RDI] and [RSI].

F2 A7 Find matching words in ES:[(E)DI] and DS:[(E)SI].

F2 A7 Find matching doublewords in ES:[(E)DI] and DS:[(E)SI].

F2 REX.W A7 Find matching doublewords in [RDI] and [RSI].

F2 AE Find AL, starting at ES:[(E)DI].

F2 REX.W AE Find AL, starting at [RDI].

F2 AF Find AX, starting at ES:[(E)DI].

F2 AF Find EAX, starting at ES:[(E)DI].

F2 REX.W AF Find RAX, starting at [RDI].

* In 64-bit mode, r/m8 can not be encoded to access the following byte registers if a REX prefix is used: AH, BH, CH, DH

Instruction Operand Encoding

Op/En

Operand 1

Operand 2

Operand 3

Operand 4

NP

NA

NA

NA

NA

Description

Repeats a string instruction the number of times specified in the count register or until the indicated condition of the ZF flag is no longer met. The REP (repeat), REPE (repeat while equal), REPNE (repeat while not equal), REPZ (repeat while zero), and REPNZ (repeat while not zero) mnemonics are prefixes that can be added to one of the string instructions. The REP prefix can be added to the INS, OUTS, MOVS, LODS, and STOS instructions, and the REPE, REPNE, REPZ, and REPNZ prefixes can be added to the CMPS and SCAS instructions. (The REPZ and REPNZ prefixes are synonymous forms of the REPE and REPNE prefixes, respectively.) The F3H prefix is defined for the following instructions and undefined for the rest:

  • F3H as REP/REPE/REPZ for string and input/output instruction.

  • F3H is a mandatory prefix for POPCNT, LZCNT, and ADOX.

The REP prefixes apply only to one string instruction at a time. To repeat a block of instructions, use the LOOP instruction or another looping construct. All of these repeat prefixes cause the associated instruction to be repeated until the count in register is decremented to 0. See Table 4-17.

Table 4-17. Repeat Prefixes

Repeat Prefix

Termination Condition 1*

Termination Condition 2

REP

RCX or (E)CX = 0

None

REPE/REPZ

RCX or (E)CX = 0

ZF = 0

REPNE/REPNZ

RCX or (E)CX = 0

ZF = 1

* Count register is CX, ECX or RCX by default, depending on attributes of the operating modes.

The REPE, REPNE, REPZ, and REPNZ prefixes also check the state of the ZF flag after each iteration and terminate the repeat loop if the ZF flag is not in the specified state. When both termination conditions are tested, the cause of a repeat termination can be determined either by testing the count register with a JECXZ instruction or by testing the ZF flag (with a JZ, JNZ, or JNE instruction).

When the REPE/REPZ and REPNE/REPNZ prefixes are used, the ZF flag does not require initialization because both the CMPS and SCAS instructions affect the ZF flag according to the results of the comparisons they make.

A repeating string operation can be suspended by an exception or interrupt. When this happens, the state of the registers is preserved to allow the string operation to be resumed upon a return from the exception or interrupt handler. The source and destination registers point to the next string elements to be operated on, the EIP register points to the string instruction, and the ECX register has the value it held following the last successful iteration of the instruction. This mechanism allows long string operations to proceed without affecting the interrupt response time of the system.

When a fault occurs during the execution of a CMPS or SCAS instruction that is prefixed with REPE or REPNE, the EFLAGS value is restored to the state prior to the execution of the instruction. Since the SCAS and CMPS instruc-tions do not use EFLAGS as an input, the processor can resume the instruction after the page fault handler.

Use the REP INS and REP OUTS instructions with caution. Not all I/O ports can handle the rate at which these instructions execute. Note that a REP STOS instruction is the fastest way to initialize a large block of memory.

In 64-bit mode, the operand size of the count register is associated with the address size attribute. Thus the default count register is RCX; REX.W has no effect on the address size and the count register. In 64-bit mode, if 67H is used to override address size attribute, the count register is ECX and any implicit source/destination operand will use the corresponding 32-bit index register. See the summary chart at the beginning of this section for encoding data and limits.

REP INS may read from the I/O port without writing to the memory location if an exception or VM exit occurs due to the write (e.g. #PF). If this would be problematic, for example because the I/O port read has side-effects, soft-ware should ensure the write to the memory location does not cause an exception or VM exit

Operation

IF AddressSize = 16
    THEN
        Use CX for CountReg;
        Implicit Source/Dest operand for memory use of SI/DI;
    ELSE IF AddressSize = 64
        THEN Use RCX for CountReg; 
        Implicit Source/Dest operand for memory use of RSI/RDI;
    ELSE
        Use ECX for CountReg;
        Implicit Source/Dest operand for memory use of ESI/EDI;
FI;
WHILE CountReg != 0
    DO
          Service pending interrupts (if any);
          Execute associated string instruction;
          CountReg <- (CountReg - 1);
          IF CountReg = 0
                THEN exit WHILE loop; FI;
          IF (Repeat prefix is REPZ or REPE) and (ZF = 0)
          or (Repeat prefix is REPNZ or REPNE) and (ZF = 1)
                THEN exit WHILE loop; FI;OD;

Flags Affected

None; however, the CMPS and SCAS instructions do set the status flags in the EFLAGS register.

Exceptions (All Operating Modes)

Exceptions may be generated by an instruction associated with the prefix.

64-Bit Mode Exceptions

#GP(0)

  • If the memory address is in a non-canonical form.