모두의 코드
IMUL (Intel x86/64 assembly instruction)
IMUL
Signed Multiply
참고 사항
아래 표를 해석하는 방법은 x86-64 명령어 레퍼런스 읽는 법 글을 참조하시기 바랍니다.
Opcode | Instruction | Op/ | 64-Bit | Compat/ | Description |
---|---|---|---|---|---|
F6 /5 | IMUL r/m8* | M | Valid | Valid | AX<- AL |
F7 /5 | IMUL r/m16 | M | Valid | Valid | DX:AX <- AX |
F7 /5 | IMUL r/m32 | M | Valid | Valid | EDX:EAX <- EAX |
REX.W + F7 /5 | IMUL r/m64 | M | Valid | N.E. | RDX:RAX <- RAX |
0F AF /r | IMUL r16 r/m16 | RM | Valid | Valid | word register <- word register |
0F AF /r | IMUL r32 r/m32 | RM | Valid | Valid | doubleword register <- doubleword register |
REX.W + 0F AF /r | IMUL r64 r/m64 | RM | Valid | N.E. | Quadword register <- Quadword register |
6B /r ib | IMUL r16 r/m16 imm8 | RMI | Valid | Valid | word register <- r/m16 |
6B /r ib | IMUL r32 r/m32 imm8 | RMI | Valid | Valid | doubleword register <- r/m32 |
REX.W + 6B /r ib | IMUL r64 r/m64 imm8 | RMI | Valid | N.E. | Quadword register <- r/m64 |
69 /r iw | IMUL r16 r/m16 imm16 | RMI | Valid | Valid | word register <- r/m16 |
69 /r id | IMUL r32 r/m32 imm32 | RMI | Valid | Valid | doubleword register <- r/m32 |
REX.W + 69 /r id | IMUL r64 r/m64 imm32 | RMI | Valid | N.E. | Quadword register <- r/m64 |
* In 64-bit mode, r/m8 can not be encoded to access the following byte registers if a REX prefix is used: AH, BH, CH, DH
Instruction Operand Encoding
Op/En | Operand 1 | Operand 2 | Operand 3 | Operand 4 |
---|---|---|---|---|
M | ModRM:r/m (r, w) | NA | NA | NA |
RM | ModRM:reg (r, w) | ModRM:r/m (r) | NA | NA |
RMI | ModRM:reg (r, w) | ModRM:r/m (r) | imm8/16/32 | NA |
Description
Performs a signed multiplication of two operands. This instruction has three forms, depending on the number of operands.
One-operand form -- This form is identical to that used by the MUL instruction. Here, the source operand (in a general-purpose register or memory location) is multiplied by the value in the AL, AX, EAX, or RAX register (depending on the operand size) and the product (twice the size of the input operand) is stored in the AX, DX:AX, EDX:EAX, or RDX:RAX registers, respectively.
Two-operand form -- With this form the destination operand (the first operand) is multiplied by the source operand (second operand). The destination operand is a general-purpose register and the source operand is an immediate value, a general-purpose register, or a memory location. The intermediate product (twice the size of the input operand) is truncated and stored in the destination operand location.
Three-operand form -- This form requires a destination operand (the first operand) and two source operands (the second and the third operands). Here, the first source operand (which can be a general-purpose register or a memory location) is multiplied by the second source operand (an immediate value). The intermediate product (twice the size of the first source operand) is truncated and stored in the destination operand (a general-purpose register).
When an immediate value is used as an operand, it is sign-extended to the length of the destination operand format.
The CF and OF flags are set when the signed integer value of the intermediate product differs from the sign extended operand-size-truncated product, otherwise the CF and OF flags are cleared.
The three forms of the IMUL instruction are similar in that the length of the product is calculated to twice the length of the operands. With the one-operand form, the product is stored exactly in the destination. With the two- and three- operand forms, however, the result is truncated to the length of the destination before it is stored in the destination register. Because of this truncation, the CF or OF flag should be tested to ensure that no significant bits are lost.
The two- and three-operand forms may also be used with unsigned operands because the lower half of the product is the same regardless if the operands are signed or unsigned. The CF and OF flags, however, cannot be used to determine if the upper half of the result is non-zero.
In 64-bit mode, the instruction's default operation size is 32 bits. Use of the REX.R prefix permits access to addi-tional registers (R8-R15). Use of the REX.W prefix promotes operation to 64 bits. Use of REX.W modifies the three forms of the instruction as follows.
One-operand form --The source operand (in a 64-bit general-purpose register or memory location) is multiplied by the value in the RAX register and the product is stored in the RDX:RAX registers.
Two-operand form -- The source operand is promoted to 64 bits if it is a register or a memory location. The destination operand is promoted to 64 bits.
Three-operand form -- The first source operand (either a register or a memory location) and destination operand are promoted to 64 bits. If the source operand is an immediate, it is sign extended to 64 bits.
Operation
IF (NumberOfOperands = 1) THEN IF (OperandSize = 8) THEN TMP_XP <- AL `*` SRC (* Signed multiplication; TMP_XP is a signed integer at twice the width of the SRC *); AX <- TMP_XP[15:0]; IF SignExtend(TMP_XP[7:0]) = TMP_XP THEN CF <- 0; OF <- 0; ELSE CF <- 1; OF <- 1; FI; ELSE IF OperandSize = 16 THEN TMP_XP <- AX `*` SRC (* Signed multiplication; TMP_XP is a signed integer at twice the width of the SRC *) DX:AX <- TMP_XP[31:0]; IF SignExtend(TMP_XP[15:0]) = TMP_XP THEN CF <- 0; OF <- 0; ELSE CF <- 1; OF <- 1; FI; ELSE IF OperandSize = 32 THEN TMP_XP <- EAX `*` SRC (* Signed multiplication; TMP_XP is a signed integer at twice the width of the SRC*) EDX:EAX <- TMP_XP[63:0]; IF SignExtend(TMP_XP[31:0]) = TMP_XP THEN CF <- 0; OF <- 0; ELSE CF <- 1; OF <- 1; FI; ELSE (* OperandSize = 64 *) TMP_XP <- RAX `*` SRC (* Signed multiplication; TMP_XP is a signed integer at twice the width of the SRC *) EDX:EAX <- TMP_XP[127:0]; IF SignExtend(TMP_XP[63:0]) = TMP_XP THEN CF <- 0; OF <- 0; ELSE CF <- 1; OF <- 1; FI; FI; FI; ELSE IF (NumberOfOperands = 2) THEN TMP_XP <- DEST `*` SRC (* Signed multiplication; TMP_XP is a signed integer at twice the width of the SRC *) DEST <- TruncateToOperandSize(TMP_XP); IF SignExtend(DEST) != TMP_XP THEN CF <- 1; OF <- 1; ELSE CF <- 0; OF <- 0; FI; ELSE (* NumberOfOperands = 3 *) TMP_XP <- SRC1 `*` SRC2 (* Signed multiplication; TMP_XP is a signed integer at twice the width of the SRC1 *) DEST <- TruncateToOperandSize(TMP_XP); IF SignExtend(DEST) != TMP_XP THEN CF <- 1; OF <- 1; ELSE CF <- 0; OF <- 0; FI; FI; FI;
Flags Affected
For the one operand form of the instruction, the CF and OF flags are set when significant bits are carried into the upper half of the result and cleared when the result fits exactly in the lower half of the result. For the two- and three-operand forms of the instruction, the CF and OF flags are set when the result must be truncated to fit in the destination operand size and cleared when the result fits exactly in the destination operand size. The SF, ZF, AF, and PF flags are undefined.
Protected Mode Exceptions
#GP(0)
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.
If the DS, ES, FS, or GS register is used to access memory and it contains a NULL NULL segment selector.
#SS(0)
If a memory operand effective address is outside the SS segment limit.
#PF(fault-code)
If a page fault occurs.
#AC(0)
If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.
#UD
If the LOCK prefix is used.
Real-Address Mode Exceptions
#GP
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.
#SS
If a memory operand effective address is outside the SS segment limit.
#UD
If the LOCK prefix is used.
Virtual-8086 Mode Exceptions
#GP(0)
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.
#SS(0)
If a memory operand effective address is outside the SS segment limit.
#PF(fault-code)
If a page fault occurs.
#AC(0)
If alignment checking is enabled and an unaligned memory reference is made.
#UD
If the LOCK prefix is used.
Compatibility Mode Exceptions
Same exceptions as in protected mode.
64-Bit Mode Exceptions
#SS(0)
If a memory address referencing the SS segment is in a non-canonical form.
#GP(0)
If the memory address is in a non-canonical form.
#PF(fault-code)
If a page fault occurs.
#AC(0)
If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.
#UD
If the LOCK prefix is used.
댓글을 불러오는 중입니다..